|
CONTROLS & CALIBRATORS
Description of Product
· Human source naturally
occurring antibodies from purified pooled sera.
· All raw materials of human
origin are tested and found negative for: HIV Ag, HBs Ag, HIV I & II
Abs, HCV Abs and a test for Syphilis, by FDA approved methods.
· Final products are
sterile filtered through 0.2 µ filters and filled into sterile
containers.
· Final products are
preserved with a suitable antimicrobial (e.g. sodium azide, proclin).
Alternatively, customers may request a specific preservative to be used.
· Positive controls may be
prepared as high titered bulk preparation which customers may dilute with
their own diluents to a suitable working dilution or to prepare
calibrators. Alternatively, customers may request that Equitech-Bio
prepare the controls and/or calibrators at a specific titer.
· Negative controls are
non-reactive for all markers and can be prepared from human source
materials or synthetic materials.
· All controls and
calibrators are stable for 1 year when stored at 2-8°C.
· All controls and
calibrators are standardized to (WHO) International Standards.
· Can be supplied to the
customer in different size containers per request.
Rheumatic Diseases Multiple
Marker Controls and Calibrators:
· Antistreptolysin O (ASO)
Positive Serum (titer adjusted to customer’s specifications).
· Rheumatoid Factor (RF) Positive
Serum (titer adjusted to customer’s specifications).
· C-Reactive Protein (CRP)
Positive Serum (titer adjusted to customer’s specifications).
ToRCH Panel Antibodies (IgM
& IgG) Positive Multiple Marker Controls and Calibrators:
ToRCH is an acronym for
a group of infectious diseases that can cause illness in pregnant women
and may cause birth defects in their newborns. The test is a screen for
the presence of antibodies to these infections. Confirmation of an active
infection may require more specific tests:
· Toxoplasma gondii
Positive Serum (titer adjusted to customer’s specifications).
· Rubella Virus Positive
Serum (titer adjusted to customer’s specifications).
· Cytomegalovirus (CMV)
Positive Serum (titer adjusted to customer’s specifications).
· Herpes Simplex Virus
(HSV)Positive Serum (titer adjusted to customer’s specifications).
Sexually Transmitted Disease
Controls and Calibrators:
· Syphilis Antibody
Positive Serum (titer adjusted to customer’s specifications).
· Herpes Simplex Virus II
(HSV) Positive Serum (titer adjusted to customer’s specifications).
Please see related
pages:
Positive Calibrators
Positive
Controls
Positive Sera/Plasma
|